Loading...
Note: File does not exist in v4.17.
1What: /sys/kernel/debug/moxtet/input
2Date: March 2019
3KernelVersion: 5.3
4Contact: Marek BehĂșn <kabel@kernel.org>
5Description: (Read) Read input from the shift registers, in hexadecimal.
6 Returns N+1 bytes, where N is the number of Moxtet connected
7 modules. The first byte is from the CPU board itself.
8
9 Example::
10
11 101214
12
13 == =======================================
14 10 CPU board with SD card
15 12 2 = PCIe module, 1 = IRQ not active
16 14 4 = Peridot module, 1 = IRQ not active
17 == =======================================
18
19What: /sys/kernel/debug/moxtet/output
20Date: March 2019
21KernelVersion: 5.3
22Contact: Marek BehĂșn <kabel@kernel.org>
23Description: (RW) Read last written value to the shift registers, in
24 hexadecimal, or write values to the shift registers, also
25 in hexadecimal.
26
27 Example::
28
29 0102
30
31 == ================================================
32 01 01 was last written, or is to be written, to the
33 first module's shift register
34 02 the same for second module
35 == ================================================