Linux Audio

Check our new training course

Loading...
Note: File does not exist in v6.13.7.
  1Kernel driver max34440
  2======================
  3
  4Supported chips:
  5  * Maxim MAX34440
  6    Prefixes: 'max34440'
  7    Addresses scanned: -
  8    Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34440.pdf
  9  * Maxim MAX34441
 10    PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller
 11    Prefixes: 'max34441'
 12    Addresses scanned: -
 13    Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34441.pdf
 14  * Maxim MAX34446
 15    PMBus Power-Supply Data Logger
 16    Prefixes: 'max34446'
 17    Addresses scanned: -
 18    Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34446.pdf
 19  * Maxim MAX34460
 20    PMBus 12-Channel Voltage Monitor & Sequencer
 21    Prefix: 'max34460'
 22    Addresses scanned: -
 23    Datasheet: http://datasheets.maximintegrated.com/en/ds/MAX34460.pdf
 24  * Maxim MAX34461
 25    PMBus 16-Channel Voltage Monitor & Sequencer
 26    Prefix: 'max34461'
 27    Addresses scanned: -
 28    Datasheet: http://datasheets.maximintegrated.com/en/ds/MAX34461.pdf
 29
 30Author: Guenter Roeck <linux@roeck-us.net>
 31
 32
 33Description
 34-----------
 35
 36This driver supports hardware monitoring for Maxim MAX34440 PMBus 6-Channel
 37Power-Supply Manager, MAX34441 PMBus 5-Channel Power-Supply Manager
 38and Intelligent Fan Controller, and MAX34446 PMBus Power-Supply Data Logger.
 39It also supports the MAX34460 and MAX34461 PMBus Voltage Monitor & Sequencers.
 40The MAX34460 supports 12 voltage channels, and the MAX34461 supports 16 voltage
 41channels.
 42
 43The driver is a client driver to the core PMBus driver. Please see
 44Documentation/hwmon/pmbus for details on PMBus client drivers.
 45
 46
 47Usage Notes
 48-----------
 49
 50This driver does not auto-detect devices. You will have to instantiate the
 51devices explicitly. Please see Documentation/i2c/instantiating-devices for
 52details.
 53
 54For MAX34446, the value of the currX_crit attribute determines if current or
 55voltage measurement is enabled for a given channel. Voltage measurement is
 56enabled if currX_crit is set to 0; current measurement is enabled if the
 57attribute is set to a positive value. Power measurement is only enabled if
 58channel 1 (3) is configured for voltage measurement, and channel 2 (4) is
 59configured for current measurement.
 60
 61
 62Platform data support
 63---------------------
 64
 65The driver supports standard PMBus driver platform data.
 66
 67
 68Sysfs entries
 69-------------
 70
 71The following attributes are supported. Limits are read-write; all other
 72attributes are read-only.
 73
 74in[1-6]_label		"vout[1-6]".
 75in[1-6]_input		Measured voltage. From READ_VOUT register.
 76in[1-6]_min		Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
 77in[1-6]_max		Maximum voltage. From VOUT_OV_WARN_LIMIT register.
 78in[1-6]_lcrit		Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register.
 79in[1-6]_crit		Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
 80in[1-6]_min_alarm	Voltage low alarm. From VOLTAGE_UV_WARNING status.
 81in[1-6]_max_alarm	Voltage high alarm. From VOLTAGE_OV_WARNING status.
 82in[1-6]_lcrit_alarm	Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
 83in[1-6]_crit_alarm	Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
 84in[1-6]_lowest		Historical minimum voltage.
 85in[1-6]_highest		Historical maximum voltage.
 86in[1-6]_reset_history	Write any value to reset history.
 87
 88			MAX34446 only supports in[1-4].
 89
 90curr[1-6]_label		"iout[1-6]".
 91curr[1-6]_input		Measured current. From READ_IOUT register.
 92curr[1-6]_max		Maximum current. From IOUT_OC_WARN_LIMIT register.
 93curr[1-6]_crit		Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
 94curr[1-6]_max_alarm	Current high alarm. From IOUT_OC_WARNING status.
 95curr[1-6]_crit_alarm	Current critical high alarm. From IOUT_OC_FAULT status.
 96curr[1-4]_average	Historical average current (MAX34446 only).
 97curr[1-6]_highest	Historical maximum current.
 98curr[1-6]_reset_history	Write any value to reset history.
 99
100			in6 and curr6 attributes only exist for MAX34440.
101			MAX34446 only supports curr[1-4].
102
103power[1,3]_label	"pout[1,3]"
104power[1,3]_input	Measured power.
105power[1,3]_average	Historical average power.
106power[1,3]_highest	Historical maximum power.
107
108			Power attributes only exist for MAX34446.
109
110temp[1-8]_input		Measured temperatures. From READ_TEMPERATURE_1 register.
111			temp1 is the chip's internal temperature. temp2..temp5
112			are remote I2C temperature sensors. For MAX34441, temp6
113			is a remote thermal-diode sensor. For MAX34440, temp6..8
114			are remote I2C temperature sensors.
115temp[1-8]_max		Maximum temperature. From OT_WARN_LIMIT register.
116temp[1-8]_crit		Critical high temperature. From OT_FAULT_LIMIT register.
117temp[1-8]_max_alarm	Temperature high alarm.
118temp[1-8]_crit_alarm	Temperature critical high alarm.
119temp[1-8]_average	Historical average temperature (MAX34446 only).
120temp[1-8]_highest	Historical maximum temperature.
121temp[1-8]_reset_history	Write any value to reset history.
122
123			temp7 and temp8 attributes only exist for MAX34440.
124			MAX34446 only supports temp[1-3].
125
126MAX34460 supports attribute groups in[1-12] and temp[1-5].
127MAX34461 supports attribute groups in[1-16] and temp[1-5].