Loading...
1What: /sys/bus/iio/devices/triggerX/master_mode_available
2KernelVersion: 4.11
3Contact: benjamin.gaignard@st.com
4Description:
5 Reading returns the list possible master modes which are:
6 - "reset" : The UG bit from the TIMx_EGR register is
7 used as trigger output (TRGO).
8 - "enable" : The Counter Enable signal CNT_EN is used
9 as trigger output.
10 - "update" : The update event is selected as trigger output.
11 For instance a master timer can then be used
12 as a prescaler for a slave timer.
13 - "compare_pulse" : The trigger output send a positive pulse
14 when the CC1IF flag is to be set.
15 - "OC1REF" : OC1REF signal is used as trigger output.
16 - "OC2REF" : OC2REF signal is used as trigger output.
17 - "OC3REF" : OC3REF signal is used as trigger output.
18 - "OC4REF" : OC4REF signal is used as trigger output.
19 Additional modes (on TRGO2 only):
20 - "OC5REF" : OC5REF signal is used as trigger output.
21 - "OC6REF" : OC6REF signal is used as trigger output.
22 - "compare_pulse_OC4REF":
23 OC4REF rising or falling edges generate pulses.
24 - "compare_pulse_OC6REF":
25 OC6REF rising or falling edges generate pulses.
26 - "compare_pulse_OC4REF_r_or_OC6REF_r":
27 OC4REF or OC6REF rising edges generate pulses.
28 - "compare_pulse_OC4REF_r_or_OC6REF_f":
29 OC4REF rising or OC6REF falling edges generate pulses.
30 - "compare_pulse_OC5REF_r_or_OC6REF_r":
31 OC5REF or OC6REF rising edges generate pulses.
32 - "compare_pulse_OC5REF_r_or_OC6REF_f":
33 OC5REF rising or OC6REF falling edges generate pulses.
34
35 +-----------+ +-------------+ +---------+
36 | Prescaler +-> | Counter | +-> | Master | TRGO(2)
37 +-----------+ +--+--------+-+ |-> | Control +-->
38 | | || +---------+
39 +--v--------+-+ OCxREF || +---------+
40 | Chx compare +----------> | Output | ChX
41 +-----------+-+ | | Control +-->
42 . | | +---------+
43 . | | .
44 +-----------v-+ OC6REF | .
45 | Ch6 compare +---------+>
46 +-------------+
47
48 Example with: "compare_pulse_OC4REF_r_or_OC6REF_r":
49
50 X
51 X X
52 X . . X
53 X . . X
54 X . . X
55 count X . . . . X
56 . . . .
57 . . . .
58 +---------------+
59 OC4REF | . . |
60 +-+ . . +-+
61 . +---+ .
62 OC6REF . | | .
63 +-------+ +-------+
64 +-+ +-+
65 TRGO2 | | | |
66 +-+ +---+ +---------+
67
68What: /sys/bus/iio/devices/triggerX/master_mode
69KernelVersion: 4.11
70Contact: benjamin.gaignard@st.com
71Description:
72 Reading returns the current master modes.
73 Writing set the master mode
74
75What: /sys/bus/iio/devices/triggerX/sampling_frequency
76KernelVersion: 4.11
77Contact: benjamin.gaignard@st.com
78Description:
79 Reading returns the current sampling frequency.
80 Writing an value different of 0 set and start sampling.
81 Writing 0 stop sampling.
82
83What: /sys/bus/iio/devices/iio:deviceX/in_count0_preset
84KernelVersion: 4.12
85Contact: benjamin.gaignard@st.com
86Description:
87 Reading returns the current preset value.
88 Writing sets the preset value.
89 When counting up the counter starts from 0 and fires an
90 event when reach preset value.
91 When counting down the counter start from preset value
92 and fire event when reach 0.
93
94What: /sys/bus/iio/devices/iio:deviceX/in_count_enable_mode_available
95KernelVersion: 4.12
96Contact: benjamin.gaignard@st.com
97Description:
98 Reading returns the list possible enable modes.
99
100What: /sys/bus/iio/devices/iio:deviceX/in_count0_enable_mode
101KernelVersion: 4.12
102Contact: benjamin.gaignard@st.com
103Description:
104 Configure the device counter enable modes, in all case
105 counting direction is set by in_count0_count_direction
106 attribute and the counter is clocked by the internal clock.
107 always:
108 Counter is always ON.
109
110 gated:
111 Counting is enabled when connected trigger signal
112 level is high else counting is disabled.
113
114 triggered:
115 Counting is enabled on rising edge of the connected
116 trigger, and remains enabled for the duration of this
117 selected mode.
118
119What: /sys/bus/iio/devices/iio:deviceX/in_count_trigger_mode_available
120KernelVersion: 4.13
121Contact: benjamin.gaignard@st.com
122Description:
123 Reading returns the list possible trigger modes.
124
125What: /sys/bus/iio/devices/iio:deviceX/in_count0_trigger_mode
126KernelVersion: 4.13
127Contact: benjamin.gaignard@st.com
128Description:
129 Configure the device counter trigger mode
130 counting direction is set by in_count0_count_direction
131 attribute and the counter is clocked by the connected trigger
132 rising edges.
1What: /sys/bus/iio/devices/triggerX/master_mode_available
2KernelVersion: 4.11
3Contact: benjamin.gaignard@st.com
4Description:
5 Reading returns the list possible master modes which are:
6
7
8 - "reset"
9 The UG bit from the TIMx_EGR register is
10 used as trigger output (TRGO).
11 - "enable"
12 The Counter Enable signal CNT_EN is used
13 as trigger output.
14 - "update"
15 The update event is selected as trigger output.
16 For instance a master timer can then be used
17 as a prescaler for a slave timer.
18 - "compare_pulse"
19 The trigger output send a positive pulse
20 when the CC1IF flag is to be set.
21 - "OC1REF"
22 OC1REF signal is used as trigger output.
23 - "OC2REF"
24 OC2REF signal is used as trigger output.
25 - "OC3REF"
26 OC3REF signal is used as trigger output.
27 - "OC4REF"
28 OC4REF signal is used as trigger output.
29
30 Additional modes (on TRGO2 only):
31
32 - "OC5REF"
33 OC5REF signal is used as trigger output.
34 - "OC6REF"
35 OC6REF signal is used as trigger output.
36 - "compare_pulse_OC4REF":
37 OC4REF rising or falling edges generate pulses.
38 - "compare_pulse_OC6REF":
39 OC6REF rising or falling edges generate pulses.
40 - "compare_pulse_OC4REF_r_or_OC6REF_r":
41 OC4REF or OC6REF rising edges generate pulses.
42 - "compare_pulse_OC4REF_r_or_OC6REF_f":
43 OC4REF rising or OC6REF falling edges generate
44 pulses.
45 - "compare_pulse_OC5REF_r_or_OC6REF_r":
46 OC5REF or OC6REF rising edges generate pulses.
47 - "compare_pulse_OC5REF_r_or_OC6REF_f":
48 OC5REF rising or OC6REF falling edges generate
49 pulses.
50
51 ::
52
53 +-----------+ +-------------+ +---------+
54 | Prescaler +-> | Counter | +-> | Master | TRGO(2)
55 +-----------+ +--+--------+-+ |-> | Control +-->
56 | | || +---------+
57 +--v--------+-+ OCxREF || +---------+
58 | Chx compare +----------> | Output | ChX
59 +-----------+-+ | | Control +-->
60 . | | +---------+
61 . | | .
62 +-----------v-+ OC6REF | .
63 | Ch6 compare +---------+>
64 +-------------+
65
66 Example with: "compare_pulse_OC4REF_r_or_OC6REF_r"::
67
68 X
69 X X
70 X . . X
71 X . . X
72 X . . X
73 count X . . . . X
74 . . . .
75 . . . .
76 +---------------+
77 OC4REF | . . |
78 +-+ . . +-+
79 . +---+ .
80 OC6REF . | | .
81 +-------+ +-------+
82 +-+ +-+
83 TRGO2 | | | |
84 +-+ +---+ +---------+
85
86What: /sys/bus/iio/devices/triggerX/master_mode
87KernelVersion: 4.11
88Contact: benjamin.gaignard@st.com
89Description:
90 Reading returns the current master modes.
91 Writing set the master mode
92
93What: /sys/bus/iio/devices/iio:deviceX/in_count0_preset
94KernelVersion: 4.12
95Contact: benjamin.gaignard@st.com
96Description:
97 Reading returns the current preset value.
98 Writing sets the preset value.
99 When counting up the counter starts from 0 and fires an
100 event when reach preset value.
101 When counting down the counter start from preset value
102 and fire event when reach 0.
103
104What: /sys/bus/iio/devices/iio:deviceX/in_count_enable_mode_available
105KernelVersion: 4.12
106Contact: benjamin.gaignard@st.com
107Description:
108 Reading returns the list possible enable modes.
109
110What: /sys/bus/iio/devices/iio:deviceX/in_count0_enable_mode
111KernelVersion: 4.12
112Contact: benjamin.gaignard@st.com
113Description:
114 Configure the device counter enable modes, in all case
115 counting direction is set by in_count0_count_direction
116 attribute and the counter is clocked by the internal clock.
117
118 always:
119 Counter is always ON.
120
121 gated:
122 Counting is enabled when connected trigger signal
123 level is high else counting is disabled.
124
125 triggered:
126 Counting is enabled on rising edge of the connected
127 trigger, and remains enabled for the duration of this
128 selected mode.
129
130What: /sys/bus/iio/devices/iio:deviceX/in_count_trigger_mode_available
131KernelVersion: 4.13
132Contact: benjamin.gaignard@st.com
133Description:
134 Reading returns the list possible trigger modes.
135
136What: /sys/bus/iio/devices/iio:deviceX/in_count0_trigger_mode
137KernelVersion: 4.13
138Contact: benjamin.gaignard@st.com
139Description:
140 Configure the device counter trigger mode
141 counting direction is set by in_count0_count_direction
142 attribute and the counter is clocked by the connected trigger
143 rising edges.