Linux Audio

Check our new training course

Loading...
v5.9
  1// SPDX-License-Identifier: GPL-2.0-or-later
  2/*
  3 * processor_thermal.c - Passive cooling submodule of the ACPI processor driver
  4 *
  5 *  Copyright (C) 2001, 2002 Andy Grover <andrew.grover@intel.com>
  6 *  Copyright (C) 2001, 2002 Paul Diefenbaugh <paul.s.diefenbaugh@intel.com>
  7 *  Copyright (C) 2004       Dominik Brodowski <linux@brodo.de>
  8 *  Copyright (C) 2004  Anil S Keshavamurthy <anil.s.keshavamurthy@intel.com>
  9 *  			- Added processor hotplug support
 10 */
 11
 12#include <linux/kernel.h>
 13#include <linux/module.h>
 14#include <linux/init.h>
 15#include <linux/cpufreq.h>
 16#include <linux/acpi.h>
 17#include <acpi/processor.h>
 18#include <linux/uaccess.h>
 19
 20#define PREFIX "ACPI: "
 21
 22#define ACPI_PROCESSOR_CLASS            "processor"
 23#define _COMPONENT              ACPI_PROCESSOR_COMPONENT
 24ACPI_MODULE_NAME("processor_thermal");
 25
 26#ifdef CONFIG_CPU_FREQ
 27
 28/* If a passive cooling situation is detected, primarily CPUfreq is used, as it
 29 * offers (in most cases) voltage scaling in addition to frequency scaling, and
 30 * thus a cubic (instead of linear) reduction of energy. Also, we allow for
 31 * _any_ cpufreq driver and not only the acpi-cpufreq driver.
 32 */
 33
 34#define CPUFREQ_THERMAL_MIN_STEP 0
 35#define CPUFREQ_THERMAL_MAX_STEP 3
 36
 37static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_pctg);
 38
 39#define reduction_pctg(cpu) \
 40	per_cpu(cpufreq_thermal_reduction_pctg, phys_package_first_cpu(cpu))
 41
 42/*
 43 * Emulate "per package data" using per cpu data (which should really be
 44 * provided elsewhere)
 45 *
 46 * Note we can lose a CPU on cpu hotunplug, in this case we forget the state
 47 * temporarily. Fortunately that's not a big issue here (I hope)
 48 */
 49static int phys_package_first_cpu(int cpu)
 50{
 51	int i;
 52	int id = topology_physical_package_id(cpu);
 53
 54	for_each_online_cpu(i)
 55		if (topology_physical_package_id(i) == id)
 56			return i;
 57	return 0;
 58}
 59
 60static int cpu_has_cpufreq(unsigned int cpu)
 61{
 62	struct cpufreq_policy policy;
 63	if (!acpi_processor_cpufreq_init || cpufreq_get_policy(&policy, cpu))
 64		return 0;
 65	return 1;
 66}
 67
 68static int cpufreq_get_max_state(unsigned int cpu)
 69{
 70	if (!cpu_has_cpufreq(cpu))
 71		return 0;
 72
 73	return CPUFREQ_THERMAL_MAX_STEP;
 74}
 75
 76static int cpufreq_get_cur_state(unsigned int cpu)
 77{
 78	if (!cpu_has_cpufreq(cpu))
 79		return 0;
 80
 81	return reduction_pctg(cpu);
 82}
 83
 84static int cpufreq_set_cur_state(unsigned int cpu, int state)
 85{
 86	struct cpufreq_policy *policy;
 87	struct acpi_processor *pr;
 88	unsigned long max_freq;
 89	int i, ret;
 90
 91	if (!cpu_has_cpufreq(cpu))
 92		return 0;
 93
 94	reduction_pctg(cpu) = state;
 95
 96	/*
 97	 * Update all the CPUs in the same package because they all
 98	 * contribute to the temperature and often share the same
 99	 * frequency.
100	 */
101	for_each_online_cpu(i) {
102		if (topology_physical_package_id(i) !=
103		    topology_physical_package_id(cpu))
104			continue;
105
106		pr = per_cpu(processors, i);
107
108		if (unlikely(!freq_qos_request_active(&pr->thermal_req)))
109			continue;
110
111		policy = cpufreq_cpu_get(i);
112		if (!policy)
113			return -EINVAL;
114
115		max_freq = (policy->cpuinfo.max_freq * (100 - reduction_pctg(i) * 20)) / 100;
116
117		cpufreq_cpu_put(policy);
118
119		ret = freq_qos_update_request(&pr->thermal_req, max_freq);
120		if (ret < 0) {
121			pr_warn("Failed to update thermal freq constraint: CPU%d (%d)\n",
122				pr->id, ret);
123		}
124	}
125	return 0;
126}
127
128void acpi_thermal_cpufreq_init(struct cpufreq_policy *policy)
129{
130	unsigned int cpu;
131
132	for_each_cpu(cpu, policy->related_cpus) {
133		struct acpi_processor *pr = per_cpu(processors, cpu);
134		int ret;
135
136		if (!pr)
137			continue;
138
139		ret = freq_qos_add_request(&policy->constraints,
140					   &pr->thermal_req,
141					   FREQ_QOS_MAX, INT_MAX);
142		if (ret < 0)
143			pr_err("Failed to add freq constraint for CPU%d (%d)\n",
144			       cpu, ret);
145	}
146}
147
148void acpi_thermal_cpufreq_exit(struct cpufreq_policy *policy)
149{
150	unsigned int cpu;
151
152	for_each_cpu(cpu, policy->related_cpus) {
153		struct acpi_processor *pr = per_cpu(processors, policy->cpu);
154
155		if (pr)
156			freq_qos_remove_request(&pr->thermal_req);
157	}
158}
159#else				/* ! CONFIG_CPU_FREQ */
160static int cpufreq_get_max_state(unsigned int cpu)
161{
162	return 0;
163}
164
165static int cpufreq_get_cur_state(unsigned int cpu)
166{
167	return 0;
168}
169
170static int cpufreq_set_cur_state(unsigned int cpu, int state)
171{
172	return 0;
173}
174
175#endif
176
177/* thermal cooling device callbacks */
178static int acpi_processor_max_state(struct acpi_processor *pr)
179{
180	int max_state = 0;
181
182	/*
183	 * There exists four states according to
184	 * cpufreq_thermal_reduction_pctg. 0, 1, 2, 3
185	 */
186	max_state += cpufreq_get_max_state(pr->id);
187	if (pr->flags.throttling)
188		max_state += (pr->throttling.state_count -1);
189
190	return max_state;
191}
192static int
193processor_get_max_state(struct thermal_cooling_device *cdev,
194			unsigned long *state)
195{
196	struct acpi_device *device = cdev->devdata;
197	struct acpi_processor *pr;
198
199	if (!device)
200		return -EINVAL;
201
202	pr = acpi_driver_data(device);
203	if (!pr)
204		return -EINVAL;
205
206	*state = acpi_processor_max_state(pr);
207	return 0;
208}
209
210static int
211processor_get_cur_state(struct thermal_cooling_device *cdev,
212			unsigned long *cur_state)
213{
214	struct acpi_device *device = cdev->devdata;
215	struct acpi_processor *pr;
216
217	if (!device)
218		return -EINVAL;
219
220	pr = acpi_driver_data(device);
221	if (!pr)
222		return -EINVAL;
223
224	*cur_state = cpufreq_get_cur_state(pr->id);
225	if (pr->flags.throttling)
226		*cur_state += pr->throttling.state;
227	return 0;
228}
229
230static int
231processor_set_cur_state(struct thermal_cooling_device *cdev,
232			unsigned long state)
233{
234	struct acpi_device *device = cdev->devdata;
235	struct acpi_processor *pr;
236	int result = 0;
237	int max_pstate;
238
239	if (!device)
240		return -EINVAL;
241
242	pr = acpi_driver_data(device);
243	if (!pr)
244		return -EINVAL;
245
246	max_pstate = cpufreq_get_max_state(pr->id);
247
248	if (state > acpi_processor_max_state(pr))
249		return -EINVAL;
250
251	if (state <= max_pstate) {
252		if (pr->flags.throttling && pr->throttling.state)
253			result = acpi_processor_set_throttling(pr, 0, false);
254		cpufreq_set_cur_state(pr->id, state);
255	} else {
256		cpufreq_set_cur_state(pr->id, max_pstate);
257		result = acpi_processor_set_throttling(pr,
258				state - max_pstate, false);
259	}
260	return result;
261}
262
263const struct thermal_cooling_device_ops processor_cooling_ops = {
264	.get_max_state = processor_get_max_state,
265	.get_cur_state = processor_get_cur_state,
266	.set_cur_state = processor_set_cur_state,
267};
v5.14.15
  1// SPDX-License-Identifier: GPL-2.0-or-later
  2/*
  3 * processor_thermal.c - Passive cooling submodule of the ACPI processor driver
  4 *
  5 *  Copyright (C) 2001, 2002 Andy Grover <andrew.grover@intel.com>
  6 *  Copyright (C) 2001, 2002 Paul Diefenbaugh <paul.s.diefenbaugh@intel.com>
  7 *  Copyright (C) 2004       Dominik Brodowski <linux@brodo.de>
  8 *  Copyright (C) 2004  Anil S Keshavamurthy <anil.s.keshavamurthy@intel.com>
  9 *  			- Added processor hotplug support
 10 */
 11
 12#include <linux/kernel.h>
 13#include <linux/module.h>
 14#include <linux/init.h>
 15#include <linux/cpufreq.h>
 16#include <linux/acpi.h>
 17#include <acpi/processor.h>
 18#include <linux/uaccess.h>
 19
 
 
 
 
 
 
 20#ifdef CONFIG_CPU_FREQ
 21
 22/* If a passive cooling situation is detected, primarily CPUfreq is used, as it
 23 * offers (in most cases) voltage scaling in addition to frequency scaling, and
 24 * thus a cubic (instead of linear) reduction of energy. Also, we allow for
 25 * _any_ cpufreq driver and not only the acpi-cpufreq driver.
 26 */
 27
 28#define CPUFREQ_THERMAL_MIN_STEP 0
 29#define CPUFREQ_THERMAL_MAX_STEP 3
 30
 31static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_pctg);
 32
 33#define reduction_pctg(cpu) \
 34	per_cpu(cpufreq_thermal_reduction_pctg, phys_package_first_cpu(cpu))
 35
 36/*
 37 * Emulate "per package data" using per cpu data (which should really be
 38 * provided elsewhere)
 39 *
 40 * Note we can lose a CPU on cpu hotunplug, in this case we forget the state
 41 * temporarily. Fortunately that's not a big issue here (I hope)
 42 */
 43static int phys_package_first_cpu(int cpu)
 44{
 45	int i;
 46	int id = topology_physical_package_id(cpu);
 47
 48	for_each_online_cpu(i)
 49		if (topology_physical_package_id(i) == id)
 50			return i;
 51	return 0;
 52}
 53
 54static int cpu_has_cpufreq(unsigned int cpu)
 55{
 56	struct cpufreq_policy policy;
 57	if (!acpi_processor_cpufreq_init || cpufreq_get_policy(&policy, cpu))
 58		return 0;
 59	return 1;
 60}
 61
 62static int cpufreq_get_max_state(unsigned int cpu)
 63{
 64	if (!cpu_has_cpufreq(cpu))
 65		return 0;
 66
 67	return CPUFREQ_THERMAL_MAX_STEP;
 68}
 69
 70static int cpufreq_get_cur_state(unsigned int cpu)
 71{
 72	if (!cpu_has_cpufreq(cpu))
 73		return 0;
 74
 75	return reduction_pctg(cpu);
 76}
 77
 78static int cpufreq_set_cur_state(unsigned int cpu, int state)
 79{
 80	struct cpufreq_policy *policy;
 81	struct acpi_processor *pr;
 82	unsigned long max_freq;
 83	int i, ret;
 84
 85	if (!cpu_has_cpufreq(cpu))
 86		return 0;
 87
 88	reduction_pctg(cpu) = state;
 89
 90	/*
 91	 * Update all the CPUs in the same package because they all
 92	 * contribute to the temperature and often share the same
 93	 * frequency.
 94	 */
 95	for_each_online_cpu(i) {
 96		if (topology_physical_package_id(i) !=
 97		    topology_physical_package_id(cpu))
 98			continue;
 99
100		pr = per_cpu(processors, i);
101
102		if (unlikely(!freq_qos_request_active(&pr->thermal_req)))
103			continue;
104
105		policy = cpufreq_cpu_get(i);
106		if (!policy)
107			return -EINVAL;
108
109		max_freq = (policy->cpuinfo.max_freq * (100 - reduction_pctg(i) * 20)) / 100;
110
111		cpufreq_cpu_put(policy);
112
113		ret = freq_qos_update_request(&pr->thermal_req, max_freq);
114		if (ret < 0) {
115			pr_warn("Failed to update thermal freq constraint: CPU%d (%d)\n",
116				pr->id, ret);
117		}
118	}
119	return 0;
120}
121
122void acpi_thermal_cpufreq_init(struct cpufreq_policy *policy)
123{
124	unsigned int cpu;
125
126	for_each_cpu(cpu, policy->related_cpus) {
127		struct acpi_processor *pr = per_cpu(processors, cpu);
128		int ret;
129
130		if (!pr)
131			continue;
132
133		ret = freq_qos_add_request(&policy->constraints,
134					   &pr->thermal_req,
135					   FREQ_QOS_MAX, INT_MAX);
136		if (ret < 0)
137			pr_err("Failed to add freq constraint for CPU%d (%d)\n",
138			       cpu, ret);
139	}
140}
141
142void acpi_thermal_cpufreq_exit(struct cpufreq_policy *policy)
143{
144	unsigned int cpu;
145
146	for_each_cpu(cpu, policy->related_cpus) {
147		struct acpi_processor *pr = per_cpu(processors, policy->cpu);
148
149		if (pr)
150			freq_qos_remove_request(&pr->thermal_req);
151	}
152}
153#else				/* ! CONFIG_CPU_FREQ */
154static int cpufreq_get_max_state(unsigned int cpu)
155{
156	return 0;
157}
158
159static int cpufreq_get_cur_state(unsigned int cpu)
160{
161	return 0;
162}
163
164static int cpufreq_set_cur_state(unsigned int cpu, int state)
165{
166	return 0;
167}
168
169#endif
170
171/* thermal cooling device callbacks */
172static int acpi_processor_max_state(struct acpi_processor *pr)
173{
174	int max_state = 0;
175
176	/*
177	 * There exists four states according to
178	 * cpufreq_thermal_reduction_pctg. 0, 1, 2, 3
179	 */
180	max_state += cpufreq_get_max_state(pr->id);
181	if (pr->flags.throttling)
182		max_state += (pr->throttling.state_count -1);
183
184	return max_state;
185}
186static int
187processor_get_max_state(struct thermal_cooling_device *cdev,
188			unsigned long *state)
189{
190	struct acpi_device *device = cdev->devdata;
191	struct acpi_processor *pr;
192
193	if (!device)
194		return -EINVAL;
195
196	pr = acpi_driver_data(device);
197	if (!pr)
198		return -EINVAL;
199
200	*state = acpi_processor_max_state(pr);
201	return 0;
202}
203
204static int
205processor_get_cur_state(struct thermal_cooling_device *cdev,
206			unsigned long *cur_state)
207{
208	struct acpi_device *device = cdev->devdata;
209	struct acpi_processor *pr;
210
211	if (!device)
212		return -EINVAL;
213
214	pr = acpi_driver_data(device);
215	if (!pr)
216		return -EINVAL;
217
218	*cur_state = cpufreq_get_cur_state(pr->id);
219	if (pr->flags.throttling)
220		*cur_state += pr->throttling.state;
221	return 0;
222}
223
224static int
225processor_set_cur_state(struct thermal_cooling_device *cdev,
226			unsigned long state)
227{
228	struct acpi_device *device = cdev->devdata;
229	struct acpi_processor *pr;
230	int result = 0;
231	int max_pstate;
232
233	if (!device)
234		return -EINVAL;
235
236	pr = acpi_driver_data(device);
237	if (!pr)
238		return -EINVAL;
239
240	max_pstate = cpufreq_get_max_state(pr->id);
241
242	if (state > acpi_processor_max_state(pr))
243		return -EINVAL;
244
245	if (state <= max_pstate) {
246		if (pr->flags.throttling && pr->throttling.state)
247			result = acpi_processor_set_throttling(pr, 0, false);
248		cpufreq_set_cur_state(pr->id, state);
249	} else {
250		cpufreq_set_cur_state(pr->id, max_pstate);
251		result = acpi_processor_set_throttling(pr,
252				state - max_pstate, false);
253	}
254	return result;
255}
256
257const struct thermal_cooling_device_ops processor_cooling_ops = {
258	.get_max_state = processor_get_max_state,
259	.get_cur_state = processor_get_cur_state,
260	.set_cur_state = processor_set_cur_state,
261};