Linux Audio

Check our new training course

Linux debugging, profiling, tracing and performance analysis training

Mar 24-27, 2025, special US time zones
Register
Loading...
v3.5.6
  1/*
  2 * processor_thermal.c - Passive cooling submodule of the ACPI processor driver
  3 *
  4 *  Copyright (C) 2001, 2002 Andy Grover <andrew.grover@intel.com>
  5 *  Copyright (C) 2001, 2002 Paul Diefenbaugh <paul.s.diefenbaugh@intel.com>
  6 *  Copyright (C) 2004       Dominik Brodowski <linux@brodo.de>
  7 *  Copyright (C) 2004  Anil S Keshavamurthy <anil.s.keshavamurthy@intel.com>
  8 *  			- Added processor hotplug support
  9 *
 10 * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 11 *
 12 *  This program is free software; you can redistribute it and/or modify
 13 *  it under the terms of the GNU General Public License as published by
 14 *  the Free Software Foundation; either version 2 of the License, or (at
 15 *  your option) any later version.
 16 *
 17 *  This program is distributed in the hope that it will be useful, but
 18 *  WITHOUT ANY WARRANTY; without even the implied warranty of
 19 *  MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU
 20 *  General Public License for more details.
 21 *
 22 *  You should have received a copy of the GNU General Public License along
 23 *  with this program; if not, write to the Free Software Foundation, Inc.,
 24 *  59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
 25 *
 26 * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 27 */
 28
 29#include <linux/kernel.h>
 30#include <linux/module.h>
 31#include <linux/init.h>
 32#include <linux/cpufreq.h>
 33
 34#include <asm/uaccess.h>
 35
 36#include <acpi/acpi_bus.h>
 37#include <acpi/processor.h>
 38#include <acpi/acpi_drivers.h>
 39
 40#define PREFIX "ACPI: "
 41
 42#define ACPI_PROCESSOR_CLASS            "processor"
 43#define _COMPONENT              ACPI_PROCESSOR_COMPONENT
 44ACPI_MODULE_NAME("processor_thermal");
 45
 46#ifdef CONFIG_CPU_FREQ
 47
 48/* If a passive cooling situation is detected, primarily CPUfreq is used, as it
 49 * offers (in most cases) voltage scaling in addition to frequency scaling, and
 50 * thus a cubic (instead of linear) reduction of energy. Also, we allow for
 51 * _any_ cpufreq driver and not only the acpi-cpufreq driver.
 52 */
 53
 54#define CPUFREQ_THERMAL_MIN_STEP 0
 55#define CPUFREQ_THERMAL_MAX_STEP 3
 56
 57static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_pctg);
 58static unsigned int acpi_thermal_cpufreq_is_init = 0;
 59
 60#define reduction_pctg(cpu) \
 61	per_cpu(cpufreq_thermal_reduction_pctg, phys_package_first_cpu(cpu))
 62
 63/*
 64 * Emulate "per package data" using per cpu data (which should really be
 65 * provided elsewhere)
 66 *
 67 * Note we can lose a CPU on cpu hotunplug, in this case we forget the state
 68 * temporarily. Fortunately that's not a big issue here (I hope)
 69 */
 70static int phys_package_first_cpu(int cpu)
 71{
 72	int i;
 73	int id = topology_physical_package_id(cpu);
 74
 75	for_each_online_cpu(i)
 76		if (topology_physical_package_id(i) == id)
 77			return i;
 78	return 0;
 79}
 80
 81static int cpu_has_cpufreq(unsigned int cpu)
 82{
 83	struct cpufreq_policy policy;
 84	if (!acpi_thermal_cpufreq_is_init || cpufreq_get_policy(&policy, cpu))
 85		return 0;
 86	return 1;
 87}
 88
 89static int acpi_thermal_cpufreq_notifier(struct notifier_block *nb,
 90					 unsigned long event, void *data)
 91{
 92	struct cpufreq_policy *policy = data;
 93	unsigned long max_freq = 0;
 94
 95	if (event != CPUFREQ_ADJUST)
 96		goto out;
 97
 98	max_freq = (
 99	    policy->cpuinfo.max_freq *
100	    (100 - reduction_pctg(policy->cpu) * 20)
101	) / 100;
102
103	cpufreq_verify_within_limits(policy, 0, max_freq);
104
105      out:
106	return 0;
107}
108
109static struct notifier_block acpi_thermal_cpufreq_notifier_block = {
110	.notifier_call = acpi_thermal_cpufreq_notifier,
111};
112
113static int cpufreq_get_max_state(unsigned int cpu)
114{
115	if (!cpu_has_cpufreq(cpu))
116		return 0;
117
118	return CPUFREQ_THERMAL_MAX_STEP;
119}
120
121static int cpufreq_get_cur_state(unsigned int cpu)
122{
123	if (!cpu_has_cpufreq(cpu))
124		return 0;
125
126	return reduction_pctg(cpu);
127}
128
129static int cpufreq_set_cur_state(unsigned int cpu, int state)
130{
131	int i;
132
133	if (!cpu_has_cpufreq(cpu))
134		return 0;
135
136	reduction_pctg(cpu) = state;
137
138	/*
139	 * Update all the CPUs in the same package because they all
140	 * contribute to the temperature and often share the same
141	 * frequency.
142	 */
143	for_each_online_cpu(i) {
144		if (topology_physical_package_id(i) ==
145		    topology_physical_package_id(cpu))
146			cpufreq_update_policy(i);
147	}
148	return 0;
149}
150
151void acpi_thermal_cpufreq_init(void)
152{
153	int i;
154
155	i = cpufreq_register_notifier(&acpi_thermal_cpufreq_notifier_block,
156				      CPUFREQ_POLICY_NOTIFIER);
157	if (!i)
158		acpi_thermal_cpufreq_is_init = 1;
159}
160
161void acpi_thermal_cpufreq_exit(void)
162{
163	if (acpi_thermal_cpufreq_is_init)
164		cpufreq_unregister_notifier
165		    (&acpi_thermal_cpufreq_notifier_block,
166		     CPUFREQ_POLICY_NOTIFIER);
167
168	acpi_thermal_cpufreq_is_init = 0;
169}
170
171#else				/* ! CONFIG_CPU_FREQ */
172static int cpufreq_get_max_state(unsigned int cpu)
173{
174	return 0;
175}
176
177static int cpufreq_get_cur_state(unsigned int cpu)
178{
179	return 0;
180}
181
182static int cpufreq_set_cur_state(unsigned int cpu, int state)
183{
184	return 0;
185}
186
187#endif
188
189int acpi_processor_get_limit_info(struct acpi_processor *pr)
190{
191
192	if (!pr)
193		return -EINVAL;
194
195	if (pr->flags.throttling)
196		pr->flags.limit = 1;
197
198	return 0;
199}
200
201/* thermal coolign device callbacks */
202static int acpi_processor_max_state(struct acpi_processor *pr)
203{
204	int max_state = 0;
205
206	/*
207	 * There exists four states according to
208	 * cpufreq_thermal_reduction_ptg. 0, 1, 2, 3
209	 */
210	max_state += cpufreq_get_max_state(pr->id);
211	if (pr->flags.throttling)
212		max_state += (pr->throttling.state_count -1);
213
214	return max_state;
215}
216static int
217processor_get_max_state(struct thermal_cooling_device *cdev,
218			unsigned long *state)
219{
220	struct acpi_device *device = cdev->devdata;
221	struct acpi_processor *pr = acpi_driver_data(device);
 
 
 
222
223	if (!device || !pr)
 
224		return -EINVAL;
225
226	*state = acpi_processor_max_state(pr);
227	return 0;
228}
229
230static int
231processor_get_cur_state(struct thermal_cooling_device *cdev,
232			unsigned long *cur_state)
233{
234	struct acpi_device *device = cdev->devdata;
235	struct acpi_processor *pr = acpi_driver_data(device);
236
237	if (!device || !pr)
 
 
 
 
238		return -EINVAL;
239
240	*cur_state = cpufreq_get_cur_state(pr->id);
241	if (pr->flags.throttling)
242		*cur_state += pr->throttling.state;
243	return 0;
244}
245
246static int
247processor_set_cur_state(struct thermal_cooling_device *cdev,
248			unsigned long state)
249{
250	struct acpi_device *device = cdev->devdata;
251	struct acpi_processor *pr = acpi_driver_data(device);
252	int result = 0;
253	int max_pstate;
254
255	if (!device || !pr)
 
 
 
 
256		return -EINVAL;
257
258	max_pstate = cpufreq_get_max_state(pr->id);
259
260	if (state > acpi_processor_max_state(pr))
261		return -EINVAL;
262
263	if (state <= max_pstate) {
264		if (pr->flags.throttling && pr->throttling.state)
265			result = acpi_processor_set_throttling(pr, 0, false);
266		cpufreq_set_cur_state(pr->id, state);
267	} else {
268		cpufreq_set_cur_state(pr->id, max_pstate);
269		result = acpi_processor_set_throttling(pr,
270				state - max_pstate, false);
271	}
272	return result;
273}
274
275const struct thermal_cooling_device_ops processor_cooling_ops = {
276	.get_max_state = processor_get_max_state,
277	.get_cur_state = processor_get_cur_state,
278	.set_cur_state = processor_set_cur_state,
279};
v3.15
  1/*
  2 * processor_thermal.c - Passive cooling submodule of the ACPI processor driver
  3 *
  4 *  Copyright (C) 2001, 2002 Andy Grover <andrew.grover@intel.com>
  5 *  Copyright (C) 2001, 2002 Paul Diefenbaugh <paul.s.diefenbaugh@intel.com>
  6 *  Copyright (C) 2004       Dominik Brodowski <linux@brodo.de>
  7 *  Copyright (C) 2004  Anil S Keshavamurthy <anil.s.keshavamurthy@intel.com>
  8 *  			- Added processor hotplug support
  9 *
 10 * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 11 *
 12 *  This program is free software; you can redistribute it and/or modify
 13 *  it under the terms of the GNU General Public License as published by
 14 *  the Free Software Foundation; either version 2 of the License, or (at
 15 *  your option) any later version.
 16 *
 17 *  This program is distributed in the hope that it will be useful, but
 18 *  WITHOUT ANY WARRANTY; without even the implied warranty of
 19 *  MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU
 20 *  General Public License for more details.
 21 *
 22 *  You should have received a copy of the GNU General Public License along
 23 *  with this program; if not, write to the Free Software Foundation, Inc.,
 24 *  59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
 25 *
 26 * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 27 */
 28
 29#include <linux/kernel.h>
 30#include <linux/module.h>
 31#include <linux/init.h>
 32#include <linux/cpufreq.h>
 33#include <linux/acpi.h>
 
 
 
 34#include <acpi/processor.h>
 35#include <asm/uaccess.h>
 36
 37#define PREFIX "ACPI: "
 38
 39#define ACPI_PROCESSOR_CLASS            "processor"
 40#define _COMPONENT              ACPI_PROCESSOR_COMPONENT
 41ACPI_MODULE_NAME("processor_thermal");
 42
 43#ifdef CONFIG_CPU_FREQ
 44
 45/* If a passive cooling situation is detected, primarily CPUfreq is used, as it
 46 * offers (in most cases) voltage scaling in addition to frequency scaling, and
 47 * thus a cubic (instead of linear) reduction of energy. Also, we allow for
 48 * _any_ cpufreq driver and not only the acpi-cpufreq driver.
 49 */
 50
 51#define CPUFREQ_THERMAL_MIN_STEP 0
 52#define CPUFREQ_THERMAL_MAX_STEP 3
 53
 54static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_pctg);
 55static unsigned int acpi_thermal_cpufreq_is_init = 0;
 56
 57#define reduction_pctg(cpu) \
 58	per_cpu(cpufreq_thermal_reduction_pctg, phys_package_first_cpu(cpu))
 59
 60/*
 61 * Emulate "per package data" using per cpu data (which should really be
 62 * provided elsewhere)
 63 *
 64 * Note we can lose a CPU on cpu hotunplug, in this case we forget the state
 65 * temporarily. Fortunately that's not a big issue here (I hope)
 66 */
 67static int phys_package_first_cpu(int cpu)
 68{
 69	int i;
 70	int id = topology_physical_package_id(cpu);
 71
 72	for_each_online_cpu(i)
 73		if (topology_physical_package_id(i) == id)
 74			return i;
 75	return 0;
 76}
 77
 78static int cpu_has_cpufreq(unsigned int cpu)
 79{
 80	struct cpufreq_policy policy;
 81	if (!acpi_thermal_cpufreq_is_init || cpufreq_get_policy(&policy, cpu))
 82		return 0;
 83	return 1;
 84}
 85
 86static int acpi_thermal_cpufreq_notifier(struct notifier_block *nb,
 87					 unsigned long event, void *data)
 88{
 89	struct cpufreq_policy *policy = data;
 90	unsigned long max_freq = 0;
 91
 92	if (event != CPUFREQ_ADJUST)
 93		goto out;
 94
 95	max_freq = (
 96	    policy->cpuinfo.max_freq *
 97	    (100 - reduction_pctg(policy->cpu) * 20)
 98	) / 100;
 99
100	cpufreq_verify_within_limits(policy, 0, max_freq);
101
102      out:
103	return 0;
104}
105
106static struct notifier_block acpi_thermal_cpufreq_notifier_block = {
107	.notifier_call = acpi_thermal_cpufreq_notifier,
108};
109
110static int cpufreq_get_max_state(unsigned int cpu)
111{
112	if (!cpu_has_cpufreq(cpu))
113		return 0;
114
115	return CPUFREQ_THERMAL_MAX_STEP;
116}
117
118static int cpufreq_get_cur_state(unsigned int cpu)
119{
120	if (!cpu_has_cpufreq(cpu))
121		return 0;
122
123	return reduction_pctg(cpu);
124}
125
126static int cpufreq_set_cur_state(unsigned int cpu, int state)
127{
128	int i;
129
130	if (!cpu_has_cpufreq(cpu))
131		return 0;
132
133	reduction_pctg(cpu) = state;
134
135	/*
136	 * Update all the CPUs in the same package because they all
137	 * contribute to the temperature and often share the same
138	 * frequency.
139	 */
140	for_each_online_cpu(i) {
141		if (topology_physical_package_id(i) ==
142		    topology_physical_package_id(cpu))
143			cpufreq_update_policy(i);
144	}
145	return 0;
146}
147
148void acpi_thermal_cpufreq_init(void)
149{
150	int i;
151
152	i = cpufreq_register_notifier(&acpi_thermal_cpufreq_notifier_block,
153				      CPUFREQ_POLICY_NOTIFIER);
154	if (!i)
155		acpi_thermal_cpufreq_is_init = 1;
156}
157
158void acpi_thermal_cpufreq_exit(void)
159{
160	if (acpi_thermal_cpufreq_is_init)
161		cpufreq_unregister_notifier
162		    (&acpi_thermal_cpufreq_notifier_block,
163		     CPUFREQ_POLICY_NOTIFIER);
164
165	acpi_thermal_cpufreq_is_init = 0;
166}
167
168#else				/* ! CONFIG_CPU_FREQ */
169static int cpufreq_get_max_state(unsigned int cpu)
170{
171	return 0;
172}
173
174static int cpufreq_get_cur_state(unsigned int cpu)
175{
176	return 0;
177}
178
179static int cpufreq_set_cur_state(unsigned int cpu, int state)
180{
181	return 0;
182}
183
184#endif
185
186/* thermal cooling device callbacks */
 
 
 
 
 
 
 
 
 
 
 
 
187static int acpi_processor_max_state(struct acpi_processor *pr)
188{
189	int max_state = 0;
190
191	/*
192	 * There exists four states according to
193	 * cpufreq_thermal_reduction_pctg. 0, 1, 2, 3
194	 */
195	max_state += cpufreq_get_max_state(pr->id);
196	if (pr->flags.throttling)
197		max_state += (pr->throttling.state_count -1);
198
199	return max_state;
200}
201static int
202processor_get_max_state(struct thermal_cooling_device *cdev,
203			unsigned long *state)
204{
205	struct acpi_device *device = cdev->devdata;
206	struct acpi_processor *pr;
207
208	if (!device)
209		return -EINVAL;
210
211	pr = acpi_driver_data(device);
212	if (!pr)
213		return -EINVAL;
214
215	*state = acpi_processor_max_state(pr);
216	return 0;
217}
218
219static int
220processor_get_cur_state(struct thermal_cooling_device *cdev,
221			unsigned long *cur_state)
222{
223	struct acpi_device *device = cdev->devdata;
224	struct acpi_processor *pr;
225
226	if (!device)
227		return -EINVAL;
228
229	pr = acpi_driver_data(device);
230	if (!pr)
231		return -EINVAL;
232
233	*cur_state = cpufreq_get_cur_state(pr->id);
234	if (pr->flags.throttling)
235		*cur_state += pr->throttling.state;
236	return 0;
237}
238
239static int
240processor_set_cur_state(struct thermal_cooling_device *cdev,
241			unsigned long state)
242{
243	struct acpi_device *device = cdev->devdata;
244	struct acpi_processor *pr;
245	int result = 0;
246	int max_pstate;
247
248	if (!device)
249		return -EINVAL;
250
251	pr = acpi_driver_data(device);
252	if (!pr)
253		return -EINVAL;
254
255	max_pstate = cpufreq_get_max_state(pr->id);
256
257	if (state > acpi_processor_max_state(pr))
258		return -EINVAL;
259
260	if (state <= max_pstate) {
261		if (pr->flags.throttling && pr->throttling.state)
262			result = acpi_processor_set_throttling(pr, 0, false);
263		cpufreq_set_cur_state(pr->id, state);
264	} else {
265		cpufreq_set_cur_state(pr->id, max_pstate);
266		result = acpi_processor_set_throttling(pr,
267				state - max_pstate, false);
268	}
269	return result;
270}
271
272const struct thermal_cooling_device_ops processor_cooling_ops = {
273	.get_max_state = processor_get_max_state,
274	.get_cur_state = processor_get_cur_state,
275	.set_cur_state = processor_set_cur_state,
276};